Application of collecter well to replace the conventional method in the northern mountainous area

Authors

  • Huy Vuong Nguyen, Tuan Pham*, Thanh Cong Nguyen, Van Quang Tran, Van Thuc Dinh

Keywords:

collector well, conventional dam, sediment accumulation, water intake

Abstract

The solution of using a collector well was investigated to take additional water, overcome the weaknesses of the conventional weir that are prone to sediment accumulation intake structures of a weir, especially at the location where weir is not needed. The solution was considered using a laboratory model at Hydraulic Construction Institute - Vietnam Academy for Water Resources. The results of model research and construction of a pilot project in Muong Lan commune, Muong Ang district, Dien Bien province show that collector well can collect water over 31 l/s ensuring water supply for more than 20 ha of rice field.

DOI:

https://doi.org/10.31276/VJST.63(6).37-40

Classification number

2.1

Author Biography

Huy Vuong Nguyen, Tuan Pham*, Thanh Cong Nguyen, Van Quang Tran, Van Thuc Dinh

Hydraulic Construction Institute, Vietnam Academy for Water Resources

Downloads

Published

2021-06-30

Received 7 April 2021; accepted 20 May 2021

How to Cite

Nguyen Huy Vuong, Pham Tuan*, Nguyen Thanh Cong, Tran Van Quang, Dinh Van Thuc. (2021). Application of collecter well to replace the conventional method in the northern mountainous area. Version B of Vietnam Journal of Science and Technology, 63(6). https://doi.org/10.31276/VJST.63(6).37-40

Issue

Section

Engineering and Technology