Analytical performance verification and reference intervals for HbA2 and HbF in adults using the MINICAP Flex Piercing system at Tuyen Quang Provincial General Hospital

Authors

  • Thi Thu Trang Nguyen*
  • Thi Nghia Hang Luong
  • Tien Dung Do
  • Ngoc Dung Nguyen
  • Thi Chinh Luu

Abstract

Objective: Verification of analytical performance and reference intervals of HbA2 and HbF in adults using the MINICAP Flex Piercing capillary hemoglobin electrophoresis system at Tuyen Quang Provincial General Hospital in 2026. Subjects and Methods: A combined study was conducted, including a laboratory experimental evaluation following CLSI EP15-A3 and CLSI EP06 guidelines, together with a cross-sectional study involving 40 healthy adults aged 18-60 years to verify reference intervals according to CLSI EP28-A3c. Results: The analytical precision of the system met the predefined acceptance criteria, with repeatability and within-laboratory reproducibility coefficients of variation (CV%) below 2.13% for HbA2 while the CV% for HbF at the single pathological control level was below 0.62%. The bias of HbA2 ranged from 1.00 to 2.73%, remaining within the allowable limit (≤2.90%), while the bias of HbF was 1.48%. The verified linear analytical ranges were 2.80-6.55% for HbA2 (R²=0.9983) and 0.00-26.35% for HbF (R²=0.9988). Among the 40 healthy participants, all results (100%) fell within the manufacturer’s proposed reference intervals. Conclusions: The HbA2 and HbF quantification method on the MINICAP Flex Piercing system demonstrated acceptable analytical performance for routine laboratory use. The verified reference intervals are suitable for the local study population and applicable at Tuyen Quang Provincial General Hospital.

DOI:

https://doi.org/10.31276/VJST.2026.4082

Classification number

2.6, 3.2

Author Biographies

Thi Thu Trang Nguyen

Tuyen Quang Provincial General Hospital, 44 Le Duan Street, Minh Xuan Ward, Tuyen Quang Province, Vietnam

Thi Nghia Hang Luong

Tuyen Quang Provincial General Hospital, 44 Le Duan Street, Minh Xuan Ward, Tuyen Quang Province, Vietnam

Tien Dung Do

National Hospital of Endocrinology, Nguyen Bo Street, Yen So Ward, Hanoi, Vietnam

Ngoc Dung Nguyen

National Institute of Hematology and Blood Transfusion, 5 Pham Van Bach Street, Cau Giay Ward, Hanoi, Vietnam

Thi Chinh Luu

Hanoi University of Public Health, 1A Duc Thang Street, Dong Ngac Ward, Hanoi, Vietnam

Downloads

Published

2026-08-28

Received 17 June 2026; revised 5 July 2026; accepted 23 July 2026

How to Cite

Nguyen Thi Thu Trang, Luong Thi Nghia Hang, Do Tien Dung, Nguyen Ngoc Dung, & Luu Thi Chinh. (2026). Analytical performance verification and reference intervals for HbA2 and HbF in adults using the MINICAP Flex Piercing system at Tuyen Quang Provincial General Hospital. Version B of Vietnam Journal of Science and Technology. https://doi.org/10.31276/VJST.2026.4082

Issue

Section

Engineering and Technology

Most read articles by the same author(s)